Air Velocity and Temperature Sensor T-DCI-F300-1A3 • T-DCI-F300-1B3 • T-DCI-F300-1C3

The F300 series is a versatile and rugged, high-performance air velocity and air temperature sensor. Designed with conformal coated electronics and sealed enclosure, the F300 is suitable for demanding applications, including those in corrosive or alkaline environments. With its robust, splash proof design, and UV tolerant construction, the F300 is designed to handle a wide range of product and process control air flow applications.

The sensor requires analog input option during RX3000 or U30 system configuration and use of a S-FS-CVIA when using the H22-001 data logger. When using a U12 data logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).

Deskripsi

Highlighted Features

This adds the ability for users to be able to measure air velocity (in ducts, e.g.) from which CFM can be computed.

 

Operating temperature range0°C to 60°C (32°F to 140°F)
Velocity range0.15 to 1.0 m/s (30 to 200 fpm)
0.5 to 10 m/s (100 to 2,000 fpm)
1.0 to 20 m/s (200 to 4,000 fpm)
Response time400ms
Storage temperature-40°C to 105°C (-40°F – 220°F)
Relative humidity (non-condensing)5-95%
Supply power requirements4.5-15 VDC, 35mA nominal
Velocity Output0-5V
Temperature output0-5V
Housing ConstructionPolycarbonate (PC), UL94-V0 (head) UL94-HB (housing)
Plenum rated cable22 AWG
Environmental ProtectionIP65 electronics, including conformal coated sensing element
Accuracy0.15 to 1.0 m/s (30 to 200 fpm): ± (1% of reading + 0.05 m/s [10 fpm])
0.5 to 10 m/s (100 to 2,000 fpm): ± (4% of reading + 0.10 m/s [20 fpm])
1.0 to 20 m/s (200 to 4,000 fpm): ± (5% of reading + 0.15 m/s [30 fpm])
Sensor Length152mm [6.0”]
Max insertion depth110 mm [4.3”]

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “Air Velocity and Temperature Sensor T-DCI-F300-1A3 • T-DCI-F300-1B3 • T-DCI-F300-1C3”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *