RMS Voltage Accuracy: |
0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
RMS Current Accuracy: |
0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
Active Power Accuracy: |
0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
Active Energy Accuracy: |
0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
Power Factor Accuracy: |
±0.02 |
Drift: |
Up to 0.5% typical within 1 year |
Resolution: |
Volts, rms |
10mV |
Amps, rms |
0.1mA |
Active Power |
10mW down to 1 watt loads @ 120VAC |
Apparent Power |
10mVA |
Power Factor |
0.01 PF |
|
Operating Environment: |
Logging: 5° to 40°C (41° to 104°F); 0 to 95% RH (non-condensing), up to 2,000 m (6,562 ft) altitude |
Operating Modes: |
Meter or logging when launched with HOBOware |
Logging Rate: |
1 second to 18 hours, 12 minutes, 15 seconds |
Statistics Sampling Rate: |
60 Hz or 16.67 mS single-cycle |
Memory Modes: |
Wrap when full or stop when full |
Start Modes: |
Immediate, push button, date & time, or next interval |
Stop Modes: |
When memory full, push button, or date & time |
Restart Mode: |
Push button |
Time Accuracy: |
±1 minute per month at 25°C (77°F), see Plot A |
Power Source: |
Line-powered with 0.92 m (3 ft) AC power cord or two AAA 1.5 V alkaline batteries, user replaceable |
Battery Life: |
2 years with line power; 6 months battery only (no line power) with logging rate of 1 minute or greater operating at 25°C (77°F) |
Memory: |
4 MB (1.4 million measurements, maximum) |
Download Type: |
USB 2.0 interface |
Full Memory Download Time: |
Approximately 1.5 minutes |
LCD: |
LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range |
Size: |
13.97 x 7.62 x 4.75 cm (5.5 x 3 x 1.87 in.) |
Weight: |
230.8 g (8.14 oz) |
Ratings: |
IP50;
UL Listed; UL Listed to Canadian safety standards |
Calibration: |
This device has been calibrated using equipment that has been tested in accordance with ANSI C12.20 0.5%. |
|
 |