Walk In Environment Testing Room

Alat Uji Baterai, Alat Uji, ruang pengujian lingkungan berjalan, Battery Tester, Battery

ruang pengujian lingkungan berjalan cocok untuk mesin lengkap atau bagian besar dengan suhu rendah, suhu tinggi, perubahan suhu tinggi-rendah, suhu konstan, tes siklus suhu rendah tinggi dll. Dimensi dan fungsi berjalan di ruangan dapat disediakan sesuai dengan spesifikasi pelanggan , Penampilan elegan dengan ruang gaya blok penerbangan, desain cerobong udara ilmiah dan dapat sesuai dengan kebutuhan klien yang berbeda. mengadopsi layar sentuh, pengontrol logika yang dapat diprogram (PLC).

Specifications

SR NO SPECIFICATION VALUE
1 temperature range +20 °c to +80 °c
2 humidity range 40% to 85% rh
3 temperaure fluctuation +/-2°c
4 humidity fluctuation +/-3%r.h
5 dimension (internal) (h x w x d) 400 x 300 x 300cm
6 dimension (external) (h x w x d) 550 x 340 x 340cm
7 rate of cooling 1c /min in average, without load
8 rate of heating 1c /min in average, without load
9 interior walls stainless steel 304
10 exterior walls steell plate with paint spray
11 temperature measurement and controller 32 bit control and monitoring system.

interface facility with rs232 / usb

temi 880 plc

12 viewing window multi pane glass window size – 250 mm x 380 mm
13 port holes 50 mm diameter for wire routing
14 power  supply  requirement three phase, ac380 v ± 10 %, 50 hz
15 sound pressure level < 72db (a)
16 condenser cooling air cooled
17 general technical specification
18 thermal cyclic chamber
18.1 chamber with internal air circulation, and all the heaters and cooling coil located behind/below the false sheet of the chamber and outside the working space
18.2 chamber provided with castor wheels for easy mobility
19 interior
19.1 test space welded vapour tight with rounded edges
19.2 the conditioning with air circulation to maintain uniform temperatur
19.3 interior have provision for arranging stainless steel
20 insulation
20.1 insulation is asbestos-free csc-free, with low thermal conductivity, polyrthene pu foam
21 cooling system
21.1 cascade type, refrigeration system with hermetically sealed refrigeration

cycles with environment and ozone friendly and chloride free refrigeration

22 door
22.1 lockable front opening, with double door latch easy to open
22. with silicon gasket for perfect sealing
23 viewing window
23.1 viewing interlock is sealed to avoid leakage and provided with heating provision to prevent condensation
24 illumination
25.1 inernallight on viewing windows with external control
26 temperature measuring and control system
26.1 the temperature measuring and control system adopts microprocessor system and provided with touch panel for monitoring and digital display:

supplied with support software

software is capable to visualize and graphical anallyse the measured & recorded value.

A. graphical representation and digital display and control of set and actual values
B. digital input and display of temperature in degree centigrade
C. with automatic and manual operation
D. fault diagnosis system
E. 120 stroage of programmes
26.2 have adjustable safety cut-out against high and low temperature
26.3 facility to programme temperature measuring using sensor pt100
27 recorder & pc connectivity
27.1 standard rs -232 interface for pc connectivity
27.2 rs-232 cable for pc connectivity along with pc connectivity software
28 port holes
28.1 each portholes provided with silicon sealing bunker (plug)
29 electrical panel
29.1 all power connectors, protection devices power control logic built in the control panel integrated to the chamber
29.2 all electrical cables tagged with id number
29.3 all electrical function circuit equipped with its own safety device that shuts down the relevant circuit or the entire test chamber if a faulty develops
29.4 all electrical systems comply with recognized technical regulation as well as with the accident prevention regulations.
30 standard protection
30.1 protective feature to be provided as follows:
A. over load trip & earth leakage trip for complete chamber
B. mcb’s for compressors, heaters and motors
C. over load trip for compressors, heaters and motors
D. over temperature cut-off for compressors
E. high pressure and low pressure trip for compressors
F. heater be cut off, if air circulation blowers are off
31 operating system
31.1 detailed operating & maintanance manual supplied in hard copy and soft copy (cd) also
31.2 the manuals include the following:
A. installation details
B. operational instruction
C. complete list parts
D. preventive maintenance procedure
E. trouble shooting measures
F. electrical circuit diagrams
G. refrigeration system details with circuit diagram
H. details technical specification of all the items like compressors, heaters ,pumps,condensers, and valves etc.