The TMC temperature probe can be used in air, soil & water work with the UX120-006M, ZW Series or U Series of data loggers. Temperature probes are available in lengths of 0.3 m (1 ft), 1.8 m (6 ft), 6.1 m, (20 ft) & 15.2 m (50 ft).
Highlighted Features
Plug directly into the external input jacks of U12, UX120, or ZW Family loggers to expand the range of measurement options and applications
In what environment does this sensor operate?
This sensor operates in indoor, outdoor and underwater environments.
What measurements does this sensor support?
The TMCx-HD sensor supports the following measurements: Temperature and Water Temperature
Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air Accuracy:
w/U12: ±0.25°C from 0° to 50°C (±0.45°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/ZW: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/UX120-006M, MX1104, and MX1105: ±0.15°C from 0° to 70°C (±0.27°F from 32° to 158°F), insert probe 2.3 cm (0.9 inches) minimum; Resolution:
w/U12: 0.03° at 20°C (0.05° at 68°F);
w/ZW: 0.02°C at 25°C (0.04°F at 77°F);
w/UX120-006M, MX1104, and MX1105: 0.002° at 25°C (0.003° at 77°F); Drift: <0.1°C (<0.2°F) per year Response time in air: 2 min. typical to 90% in air moving 1 m/sec (2.2 mph) Response time in stirred water: 30 sec. typical to 90%. Operating range: Sensor tip and cable immersion in fresh water up to +50°C (122°F) for 1 year Housing: Copper-plated sensor tip Dimensions: 5.1 x 33 mm (0.2 x 1.3 inches) Weight: 34 g (1.1 oz)