Deskripsi
Portable Digital Coating Thickness Gauge TIME®2600 adopts two thickness-measuring methods: magnetic induction (ferrous) and eddy current (non-ferrous). It can rapidly, nondestructively, and precisely measure the thickness of non-magnetic coating on magnetic metal substrate, and the thickness of non-conductive coating on non-magnetic metal substrate. This paint meter can be euipped with 6 optional probes for different applications. It is suitable for both field testing and laboratory research.
Features
- Two operation principles are adapted: magnetic induction (ferrous) and eddy current (non-ferrous) to take non-destructive measurements
- 6 types of probes are available for different applications
- Features two working modes: DIRECT and BATCH& two measuring ways: CONTINUE and SINGLE
- Statistics include the mean, maximum, minimum, test numbers and standard deviation.
- Memory of 640 data
- Two calibration methods for better correction
- Integrated with printer to print the statists values if needed
- Low battery indication and error alarm
- Backlight for the screen
- Auto or manual shutdown
- Conform to the standards of DIN, ISO, ASTMBS.
Spesification
Technical Specification
Probe types | F | N | |
Measuring methods | magnetic induction | eddy current | |
Measuring range | 0 ~1250 μm | 0 ~1250 μm, 0 to 40μm (for chrome plate on copper) | |
Minimum resolution | 0.1μm | ||
Tolerance | Zero point calibration | ±(3%H+1)μm | ± (3%H+1.5)μm |
H means the thickness of tested piece | |||
Two points calibration | ±[(1~3)%H+1]μm | ±[(1~3)%H+1.5]μm | |
H means the thickness of tested piece | |||
Measuring condition | Min. curvature radius (mm) | Convexity 1.5 | Convexity 3 |
Min. testing area diameter (mm) | Ø7 | Ø5 | |
Critical thickness of substrate(mm) | 0.5 | 0.3 | |
Standards | DIN,ISO,ASTM,BS | ||
Calibration | Zero and foil calibration | ||
Interface | RS232 | ||
Statistic | Number of measurement, mean, standarddeviation, maximum and minimum | ||
Data memory | 640 readings | ||
Limits | Adjustable with alarm | ||
Power | NiMH rechargeable battery | ||
Operating environment | Temperature: 0~40? | ||
Humidity: 20%~90% | |||
No strong magnetic field | |||
Dimensions (mm) | 230×86×47 |
Optional Probes and Application Guide
Probe model | F400 | F1 | F1/90º | F10 | N1 | CN02 | |
Operating principle | Magnetic induction | Eddy current | |||||
Measuring range (µm) | 0-400 | 0-1250 | 0-10000 | 0 to 1250 μm | 10~200 | ||
Low range resolution (µm) | 0.1 | 0.1 | 10 | 0.1 | 1 | ||
Accuracy | One-point calibration (µm) | ±(3%H+1) | ±(3%H+10) | ±(3%H+1.5) | ±(3%H+1) | ||
Two-point calibration (µm) | ±[(1~3)H%+0.7] | ±[(1~3)H%+1] | ±[(1~3)%H+10] | ±[(1~3)%H+1.5] | – | ||
Measuring conditions | Min curvature of the min area (mm) | Convex 1 | 1.5 | Flatten | 10 | 3 | Flatten |
Diameter of the min area (mm) | φ3 | φ7 | φ7 | φ40 | φ5 | φ7 | |
Critical thickness of substrate (mm) | 0.2 | 0.5 | 0.5 | 2 | 0.3 | unlimited |
Ulasan
Belum ada ulasan.