Compressed Air Flow Meter – 40-600 SCFM Sensor T-CDI-5400-20S
Effectively monitor compressed air systems with the T-CDI-5400-20S. This flow meter includes two probes, one warmer than the other. This arrangement calculates mass velocity based on heat requirements. Additionally, pipe area data is used to determine flow amounts. This product fits a two-inch steel pipe.
Accuracy: 5% of reading plus 1% of full scale @ air temperatures 40 – 120F; (5400 model extended range) 7% of reading from rated fule scale to 150% of calibrated range, @ air temperatures 40 – 120F
Medium: Compressed air, nitrogen
Operating pressure: 200 psig max on Sch 40 steel
Input power: 250 mA @ 18 – 24 VDC
Output resistance: 400Ω max
Response time: 1 sec to 63% of final value
Output: selectable 4 – 20mA or pulse
Display: 4-digit LED
Ring material: Aluminum
Size / Weight: 3.2×2.2×1.6 in / approx. 1.4 lb
Note: Recommended: Drill Guide that facilitates accurately locating the holes that are needed to mount the flowmeter.